Setaflash Series 8 Activecool Flash Point Tester
By PT LABODIA PRIMA
· 03/10/2010
The Setaflash Series 8 'ActiveCool' is an automated closed cup flash point tester with a temperature range of 10 to 130°C (50 to 266°F) with no external cooling. When connected to a suitable chilled water supply, the range is extended down to -20°C (-4°F). There are two modes of operation; Flash / No Flash and Ramp. The ramp mode increases the sample temperature at a rate of 2°C/min automatically dips the ignitor every 1°C up to 100°C (every 2°C above 100°C), until either a flash is detected or the end of test temperature is reached. 10°C to 130°C (-20°C with external water supply) Small sample size, 2 or 4ml Flash/No Flash & Ramp modes Electric ignitor (gas available using optional accessory) Automatic dipping and flash detection ActiveCool electronic Peltier cooling 64 Test memory & RS232 interface °C or °F temperature display Temperature Range: Air: 10 to 130°C (50 to 266°F) Water Assisted: -20 to 130°C (-4 to 266°F) using 99300-2 Sample Size: 2 or 4ml according to method Ignitor: Electrical Hot Wire (optional Gas Flame) Test duration, Rapid Equilibrium Mode: 1 minute below 100°C, 2 minutes above 100°C, FAME 1 minute or user defined 1 to 99 minutes Test duration, Ramp Mode: Typically 7 minutes Methods ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 3900 Part A13, BS 6664 Parts 3 & 4, CHIPS Regulations, EPA 1020 A & B, IP 523, IP 524, IP 534, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids DETAILS OF METHODSCHIPS Regulations Chemicals Hazard Information and Packaging for Supply EPA 1020 A & B Setaflash Closed-Cup Method for determining ignitability ASTM D3828 Standard Test Methods for Flash Point by Small Scale Closed Tester IP 523 Determination of flash point. Rapid equilibrium closed cup method IP 524 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method) ASTM D7236 Flash Point by Small Scale Closed Cup Ramp Method IP 534 Flash Point by Small Scale Closed Cup Ramp Method ASTM D3278 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus - The test methods are applicable to paints, enamels, lacquers, varnishes, and related products having a flash point between 0 and 110°C (32 and 230°F) and Viscosity lower than 150 St at 25°C (77°F). ISO 3680 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (rapid equilibrium method) UN Class 3 Non-viscous Flammable Liquids Small scale flash point testers are universally specified in many international regulations to define and classify "flammable" and "combustible" substances. ASTM E502 Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods ISO 3679 Determination of flash point. Rapid equilibrium closed cup method BS 6664 Parts 3 & 4 Methods of test for paints. Tests on liquid paints (excluding chemical tests). Test for flash/no flash (closed cup equilibrium method) BS 3900 Part A13 Test for flash/no flash (rapid equilibrium method) Size (HxWxD) 30 x 34 x 38cm Weight 8 kg CCCN Code: Tariff 90268020
About This Author
PT LABODIA PRIMA
jakarta, Dki Jakarta, Indonesia
PT. LABODIA PRIMA, perusahaan yang bergerak dalam bidang pengadaan alat-alat laboratorium, alat gelas dan bahan kimia untuk industri, pendidikan dan penelitian. Dengan latar belakang pengalaman kami selama ± 13 tahun yang didukung oleh Sales & Technician Team yang professional, serta Jaminan / Garan…
More Articles From This Author
Aluminium bottle UN - BUERKLE
2011-05-11Aluminium transport bottles with screw cap close safely and tightly and are approved for packaging type I (X). The UN code is printed onto the bottles in black.Pure aluminium (material AL 99.5)FKM sealUN approvedWith eyelets, sterilisableCa… Read More »
OTAL hand pump made of PP - BUERKLE
2011-05-11The telescopic immersion tube adapts itself to the container height on insertion. This ensures good removal of residual liquid and means that the pump can be used with different containers.OTAL hand pumps with PP delivery tubes, resistant t… Read More »
OTAL foot pump made of PP - BUERKLE
2011-05-11The telescopic immersion tube adapts itself to the container height on insertion. This ensures good removal of residual liquid and means that the pump can be used with different containers.OTAL foot pumps with delivery tubes made of PP, res… Read More »
Liquid-Sampler, open with thumb - BUERKLE
2011-05-11Liquid-Sampler, open with thumb - BUERKLESampler for thin to viscous liquids. Easy use with one-handed operation. With discharge funnel for safe filling of the sample bottles. Material V4A (1.4404).The valve is opened with the thumb to empt… Read More »
MicroSampler - BUERKLE
2011-05-11The MicroSampler has especially been designed for the sampling of small quantities of powder.Volumes of 0.2 ml, 0.5 ml, 1.0 ml, 2.0 ml, 5.0 ml and 10 ml can be sampled easily, quickly and cleanly from different sampling depths from sacks or… Read More »